Better testing
This commit is contained in:
+146
@@ -0,0 +1,146 @@
|
||||
'use strict';
|
||||
|
||||
var larvitsmpp = require('../larvitsmpp'),
|
||||
assert = require('assert');
|
||||
|
||||
describe('PDU convertion', function() {
|
||||
|
||||
describe('No TLVs', function() {
|
||||
it('should build a PDU buffer for bind_transceiver_resp with error correctly', function(done) {
|
||||
larvitsmpp.objToPdu({
|
||||
'cmdName': 'bind_transceiver_resp',
|
||||
'cmdStatus': 'ESME_RALYBND',
|
||||
'seqNr': 1
|
||||
}, function(err, pdu) {
|
||||
assert( ! err, 'Error should be negative');
|
||||
|
||||
assert(pdu.readUInt32BE(0) === 17, 'Command length should be 17, but is: "' + pdu.readUInt32BE(0) + '"');
|
||||
assert(pdu.readUInt32BE(4).toString(16) === '80000009', 'Command ID should be 0x80000009');
|
||||
assert(pdu.readUInt32BE(8).toString(16) === '5', 'Command status should be 0x00000005');
|
||||
assert(pdu.readUInt32BE(12).toString(10) === '1', 'Sequence number should be 1');
|
||||
|
||||
done();
|
||||
});
|
||||
});
|
||||
|
||||
it('should be able to do the above test and put it back to an object', function(done) {
|
||||
larvitsmpp.objToPdu({
|
||||
'cmdName': 'bind_transceiver_resp',
|
||||
'cmdStatus': 'ESME_RALYBND',
|
||||
'seqNr': 1
|
||||
}, function(err, pdu) {
|
||||
assert( ! err, 'Error should be negative');
|
||||
|
||||
larvitsmpp.pduToObj(pdu, function(err, obj) {
|
||||
assert( ! err, 'Error should be negative');
|
||||
|
||||
assert(obj.cmdId.toString(16) === '80000009', 'Command ID should be 0x80000009');
|
||||
assert(obj.cmdStatus === 'ESME_RALYBND', 'Command status should be "ESME_RALYBND"');
|
||||
assert(obj.seqNr === 1, 'Sequence number should be 1');
|
||||
|
||||
done();
|
||||
});
|
||||
});
|
||||
});
|
||||
|
||||
it('should parse a PDU to obj correctly', function(done) {
|
||||
var pdu = new Buffer('0000002F000000020000000000000001534D50503354455354007365637265743038005355424D4954310000010100', 'hex');
|
||||
|
||||
larvitsmpp.pduToObj(pdu, function(err, obj) {
|
||||
assert( ! err, 'Error should be negative');
|
||||
|
||||
assert(obj.cmdId === 2, 'Command ID should be 2');
|
||||
assert(obj.cmdStatus === 'ESME_ROK', 'Command status should be "ESME_ROK"');
|
||||
assert(obj.cmdName === 'bind_transmitter', 'Command name should be "bind_transmitter"');
|
||||
assert(obj.params.system_id === 'SMPP3TEST', 'system_id should be "SMPP3TEST"');
|
||||
assert(obj.params.interface_version === 0, 'Interface version should be 0');
|
||||
|
||||
done();
|
||||
});
|
||||
});
|
||||
|
||||
it('should create a return PDU without error', function(done) {
|
||||
var pdu = new Buffer('0000002f000000020000000000000001534d50503354455354007365637265743038005355424d4954310000010100', 'hex');
|
||||
|
||||
larvitsmpp.pduReturn(pdu, function(err, retPdu) {
|
||||
assert( ! err, 'Error should be negative');
|
||||
|
||||
larvitsmpp.pduToObj(retPdu, function(err, retObj) {
|
||||
assert( ! err, 'Error should be negative');
|
||||
|
||||
assert(retObj.cmdId === 2147483650, 'Command ID should be 2147483650');
|
||||
assert(retObj.cmdStatus === 'ESME_ROK', 'Command status should be "ESME_ROK"');
|
||||
assert(retObj.cmdName === 'bind_transmitter_resp', 'Command name should be "bind_transmitter_resp"');
|
||||
assert(retObj.params.system_id === 'SMPP3TEST', 'system_id should be "SMPP3TEST"');
|
||||
|
||||
done();
|
||||
});
|
||||
});
|
||||
});
|
||||
|
||||
it('should read a submit_sm with an ending NULL octet to the short_message', function(done) {
|
||||
var pdu = new Buffer('0000003c0000000400000000000000020001003436373031313333313131000101343637303937373133333700000000000000000100047465737400', 'hex');
|
||||
|
||||
larvitsmpp.pduToObj(pdu, function(err, obj) {
|
||||
assert( ! err, 'Error should be negative');
|
||||
|
||||
assert(obj.params.short_message === 'test', 'Param short_message should read "test"');
|
||||
assert(obj.cmdLength === 60, 'Command length should be 60, due to the trailing NULL octet');
|
||||
|
||||
done();
|
||||
});
|
||||
});
|
||||
|
||||
it('should read a submit_sm without an ending NULL octet to the short_message', function(done) {
|
||||
var pdu = new Buffer('0000003b00000004000000000000000200010034363730313133333131310001013436373039373731333337000000000000000001000474657374', 'hex');
|
||||
|
||||
larvitsmpp.pduToObj(pdu, function(err, obj) {
|
||||
assert( ! err, 'Error should be negative');
|
||||
|
||||
assert(obj.params.short_message === 'test', 'Param short_message should read "test"');
|
||||
assert(obj.cmdLength === 59, 'Command length should be 59');
|
||||
|
||||
done();
|
||||
});
|
||||
});
|
||||
|
||||
it('should create a very simple submit_sm PDU', function(done) {
|
||||
larvitsmpp.objToPdu({
|
||||
'cmdName': 'submit_sm',
|
||||
'cmdStatus': 'ESME_ROK',
|
||||
'seqNr': 12,
|
||||
'params': {
|
||||
'source_addr': '46701113311',
|
||||
'destination_addr': '46709771337',
|
||||
'short_message': 'Hello world'
|
||||
}
|
||||
}, function(err, pdu) {
|
||||
assert( ! err, 'Error should be negative');
|
||||
|
||||
assert(pdu.toString('hex') === '0000004200000004000000000000000c00000034363730313131333331310000003436373039373731333337000000000000000001000b48656c6c6f20776f726c64');
|
||||
|
||||
done();
|
||||
});
|
||||
});
|
||||
|
||||
it('should create a submit_sm PDU with UCS2 encoding', function(done) {
|
||||
larvitsmpp.objToPdu({
|
||||
'cmdName': 'submit_sm',
|
||||
'cmdStatus': 'ESME_ROK',
|
||||
'seqNr': 12,
|
||||
'params': {
|
||||
'source_addr': '46701113311',
|
||||
'destination_addr': '46709771337',
|
||||
'short_message': 'Hello«»world'
|
||||
}
|
||||
}, function(err, pdu) {
|
||||
assert( ! err, 'Error should be negative');
|
||||
|
||||
assert(pdu.toString('hex') === '0000004f00000004000000000000000c00000034363730313131333331310000003436373039373731333337000000000000000008001800480065006c006c006f00ab00bb0077006f0072006c0064');
|
||||
|
||||
done();
|
||||
});
|
||||
});
|
||||
});
|
||||
|
||||
});
|
||||
Reference in New Issue